Such samples can be made as frozen solutions, avoiding the proble

Such samples can be made as frozen solutions, avoiding the problems of trying to obtain single crystals. The study by this technique of trapped intermediates and treated samples has yielded insights into the mechanism of the reaction involved, in several biological systems.   (4) Damage to biological samples by X-rays is cause for serious concern for X-ray crystallography and XAS experiments. However, with the right precautions one can successfully perform these experiments leaving the materials largely intact. The most serious damage is produced by the reaction with free radicals and hydrated electrons that are produced in

biological samples CDK inhibitor by X-rays. The diffusion of the free radicals and hydrated electrons can be minimized by the use of low temperatures. The use of a liquid He flow cryostat or liquid He cryostream, where the samples are at atmospheric pressure in a He gas atmosphere, has greatly reduced the risk of sample damage by X-rays. XAS experiments require a lower X-ray dose than X-ray crystallography, and radiation damage can be precisely monitored and controlled, thus allowing

for data collection from an intact metal cluster (Yano et al. 2005b; Corbett et al. 2007).   Limitations (1) It is also important to realize Metformin clinical trial the intrinsic limitations of EXAFS, beyond those of a purely experimental nature. A frequent problem is the inability to distinguish between scattering atoms with little difference in atomic number (C, N, O or S, Cl, or Mn, Fe). Care must also be exercised when deciding between atoms that are apart in Z, as frequently, it is possible to obtain equally good fits using backscattering atoms which are very different in Z (e.g., Mn or Cl), but which are at different distances from the absorbing atom. This is more acute when dealing with Fourier peaks at greater distances. In bridged multinuclear centers, it is not always possible to unequivocally assign the Fourier peaks at >3 Å Pyruvate dehydrogenase lipoamide kinase isozyme 1 (Scott and Eidsness

1988).   (2) Distances are usually the most reliably determined structural parameters from EXAFS. But the range of data that can be collected, often-times due to practical reasons like the presence of the K-edge of another metal, limits the resolution of distance determinations to between 0.1 and 0.2 Å. Also it is difficult to determine whether a Fourier peak should be fit to one distance with a relatively large disorder parameter or to two distances, each having a small disorder parameter. Careful statistical analysis, taking into consideration the degrees of freedom in the fits, should precede any such analysis. The resolution in the distance Δr can be estimated from the relation that ΔrΔk ~ 1 (see “Range-extended XAS”).   (3) Determination of coordination numbers or number of backscatterers is fraught with difficulties.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>