“Purpose: To evaluate the safety and efficacy of urgent ca


“Purpose: To evaluate the safety and efficacy of urgent carotid artery stenting (CAS) with technical modifications in patients with recent (<24 hours) initial or recurrent (>= 2 episodes in 24 hours) transient ischemic attacks (TIA) or with minor stroke.\n\nMethods: A single-center, prospective, observational study was begun in March 2005 to assess an urgent CAS protocol for the treatment of selected high-risk patients with carotid artery disease who presented CBL0137 molecular weight within 24 hours of an initial or recurrent TIA or minor stroke. Up to June 2011, 78 patients (59 men; mean age 76 years) with TIA (n=57) or minor stroke (n=21) underwent urgent CAS (within 48 hours)

for severe internal carotid artery stenosis. Outcome measures were major adverse cardiac and cerebrovascular events (MACCE), modifications in the National Institutes of Health Stroke Scale (NIHSS) values GDC-0068 chemical structure for minor stroke patients, and postoperative stroke and death rates.\n\nResults: Technical and procedural success rates were 100% and 97.4%, respectively; 1 intraoperative minor stroke occurred due to stent thrombosis. At 30 days, 2 patients had recurrent minor stroke; one subsequently died after a hemorrhagic brain infarction. The MACCE rate was 3.8%. There were

no cases of myocardial infarction or access-related complications. Of the 20 surviving minor stroke patients, 14 showed improvement in neurological deficit on the NIHSS scale at 30 days, while 5 remained stable and one was neurologically impaired.\n\nConclusion: Urgent CAS in selected patients with symptomatic carotid stenosis was satisfactory in preventing the GSK1120212 ic50 recurrence of TIA and stroke in this study. Urgent CAS with careful patient selection, contemporary tools (medical and technical), and expert technique may represent a possible solution for some patients with recent or recurrent TIA or minor stroke. J Endovasc Thor. 2012;19:627-635″
“The radiofrequency quadrupole linear ion trap is a widely used device in physics and chemistry. When used for trapping of large ion clouds, the presence

of anharmonic terms in the radiofrequency potential limits the total number of stored ions. In this paper, we have studied the anharmonic content of the trapping potential for different implementations of a quadrupole trap, searching for the geometry best suited for the trapping of large ion clouds. This is done by calculating the potential of a real trap using SIMION8.0, followed by a fit, which allows us to obtain the evolution of anharmonic terms fora large part of the inner volume of the trap. (C) 2009 Elsevier B.V. All rights reserved.”
“Epidemiology and resistance patterns of bacterial pathogens in pediatric urinary tract infections (UTIs) show large inter-regional variability, and rates of bacterial resistance are changing due to different antibiotic treatment policy.

Leave a Reply

Your email address will not be published. Required fields are marked *

*

You may use these HTML tags and attributes: <a href="" title=""> <abbr title=""> <acronym title=""> <b> <blockquote cite=""> <cite> <code> <del datetime=""> <em> <i> <q cite=""> <strike> <strong>