Another meta-analysis reported a specificity of 98.8%. A systematic review reported a specificity of 97%. An RCT reported a specificity of 96.2-100%. We conclude that the FNA for lung cancer is reported to be highly specific prior to major lung resection with a very low BTSA1 solubility dmso false positive rate. However, although a false positive may occasionally be acceptable in lobectomies, where the lobes are often removed without histology, all steps should be taken to avoid a false positive result in pneumonectomy considering the serious consequences of embarking upon such an operation in the small number of patients with a false positive result, and we recommend that a positive FNA result should be confirmed by means of alternative sampling

methods. We also acknowledge that obtaining an additional biopsy specimen would add to the risk of morbidity and costs; therefore, any benefits should be weighed against risks and additional costs.”
“Background

Little is known about the clinical features, procedural risks, or survival of patients receiving replacement versus new implantable cardioverter-defibrillators (ICDs).

Methods and Results

Entries in the National Cardiovascular Data Registry (NCDR) ICD Registry from 2005 through 2010 were eligible for inclusion (n=463978). Baseline demographic data, clinical information, R788 cell line and procedural variables were compared between patients receiving new (n=359993; 77.6%)

and replacement (n=103985; 22.4%) ICDs and entered into a propensity match model to determine adjusted survival rates. Patients

receiving replacement ICDs were older (70.7 versus 67.5 years of age) and more likely to have atrial fibrillation (41.8% versus 31.4%; P<0.001) and ventricular tachycardia (60.5% versus 33.9%; P<0.001) compared with patients receiving new ICDs. Median battery life was only 4.6 years (25%-75% interquartile range, 3.7-5.8) for all replaced devices, 5.8 (25%-75% interquartile range, 4.2-7.5) for single-chamber, 5.1 (25%-75% interquartile range, 4.1-6.1) for dual-chamber, and 3.9 (25%-75% interquartile range, 3.2-4.6) years for biventricular devices. Patients receiving replacement ICDs had lower rates of index admission complications (0.9% versus 3.2%; P<0.001) but greater risk for death compared receiving patients receiving new ICDs in unadjusted analysis WZB117 clinical trial (hazard ratio, 1.18; 95% confidence interval, 1.16-1.20; P<0.0001) and after propensity-score matching (hazard ratio, 1.28; 95% confidence interval, 1.25-1.30; P<0.0001).

Conclusions

Patients receiving replacement ICDs are older and at greater risk for death compared with those receiving initial ICD implants. The battery life of initial ICDs is shorter than previously reported.”